Contents | < Browse | Browse >
NAME
SUB -- Subtract
SYNOPSIS
SUB <ea>,Dn
SUB Dn,<ea>
Size = (Byte, Word, Long)
FUNCTION
Subtracts source operand to destination operand.
Result is stored to destination's place.
FORMAT
-----------------------------------------------------------------
|15 |14 |13 |12 |11 |10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|---|---|---|---|-----------|-----------|-----------|-----------|
| 1 | 0 | 0 | 1 | REGISTER | OP-MODE | MODE | REGISTER |
----------------------------------------=========================
<ea>
OP-MODE
Byte Word Long
~~~~ ~~~~ ~~~~
000 001 010 (Dn) - (<ea>) -> Dn
100 101 110 (<ea>) - (Dn) -> <ea>
REGISTER
One of the 8 datas registers
If <ea> is source, allowed addressing modes are:
--------------------------------- -------------------------------
|Addressing Mode|Mode| Register | |Addressing Mode|Mode|Register|
|-------------------------------| |-----------------------------|
| Dn |000 |N° reg. Dn| | Abs.W |111 | 000 |
|-------------------------------| |-----------------------------|
| An * |001 |N° reg. An| | Abs.L |111 | 001 |
|-------------------------------| |-----------------------------|
| (An) |010 |N° reg. An| | (d16,PC) |111 | 010 |
|-------------------------------| |-----------------------------|
| (An)+ |011 |N° reg. An| | (d8,PC,Xi) |111 | 011 |
|-------------------------------| |-----------------------------|
| -(An) |100 |N° reg. An| | (bd,PC,Xi) |111 | 011 |
|-------------------------------| |-----------------------------|
| (d16,An) |101 |N° reg. An| |([bd,PC,Xi],od)|111 | 011 |
|-------------------------------| |-----------------------------|
| (d8,An,Xi) |110 |N° reg. An| |([bd,PC],Xi,od)|111 | 011 |
|-------------------------------| |-----------------------------|
| (bd,An,Xi) |110 |N° reg. An| | #data |111 | 100 |
|-------------------------------| -------------------------------
|([bd,An,Xi]od) |110 |N° reg. An|
|-------------------------------|
|([bd,An],Xi,od)|110 |N° reg. An|
---------------------------------
* Word or Long only
If <ea> is destination, allowed addressing modes are:
--------------------------------- -------------------------------
|Addressing Mode|Mode| Register | |Addressing Mode|Mode|Register|
|-------------------------------| |-----------------------------|
| Dn | - | - | | Abs.W |111 | 000 |
|-------------------------------| |-----------------------------|
| An | - | - | | Abs.L |111 | 001 |
|-------------------------------| |-----------------------------|
| (An) |010 |N° reg. An| | (d16,PC) | - | - |
|-------------------------------| |-----------------------------|
| (An)+ |011 |N° reg. An| | (d8,PC,Xi) | - | - |
|-------------------------------| |-----------------------------|
| -(An) |100 |N° reg. An| | (bd,PC,Xi) | - | - |
|-------------------------------| |-----------------------------|
| (d16,An) |101 |N° reg. An| |([bd,PC,Xi],od)| - | - |
|-------------------------------| |-----------------------------|
| (d8,An,Xi) |110 |N° reg. An| |([bd,PC],Xi,od)| - | - |
|-------------------------------| |-----------------------------|
| (bd,An,Xi) |110 |N° reg. An| | #data | - | - |
|-------------------------------| -------------------------------
|([bd,An,Xi]od) |110 |N° reg. An|
|-------------------------------|
|([bd,An],Xi,od)|110 |N° reg. An|
---------------------------------
When destination is an Address Register, SUBA instruction is used.
RESULT
X - Set the same as the carry bit.
N - Set if the result is negative. Cleared otherwise.
Z - Set if the result is zero. Cleared otherwise.
V - Set if an overflow is generated. Cleared otherwise.
C - Set if a carry is generated. Cleared otherwise.
SEE ALSO
ADDI ADDQ ADDX
ADD SUBI SUBQ
SUBX